Luciferase Rabbit Polyclonal Antibody
Product Data | |
Application | ELISA, ID, IF, IP, R, WB |
---|---|
Recommended Dilution | This product is intended for use in precipitating and non-precipitating antibody-binding assays such as e.g., ELISA and Western blotting and Immunofluorescence or Histochemical techniques (1/10,000-1/100,000). |
Reactivity | Photinus pyralis |
Antibody Host | Rabbit |
Isotype | IgG |
Clonality | Polyclonal |
Immunogen | Luciferase isolated and purified from Photinus pyralis. Freund’s complete adjuvant is used in the first step of the immunization procedure. |
Specificity | The reagents were evaluated for potency, purity and specificity using most or all of the following techniques: Immunoelectrophoresis, Cross-Immunoelectrophoresis, single Radial Immunodiffusion (Ouchterlony), block titration, ELISA, Immunoblotting and Enzyme Inhibition. Cross-reactivities against enzymes of other sources may occur but have not been determined. |
Buffer | PBS, pH 7.2 stabilized with Dextran without preservatives and foreign proteins. State: Aff - Purified State: Lyophilized purified IgG fraction |
Reconstitution Method | Restore by adding 0.5 ml of sterile distilled water. |
Concentration | lot specific |
Purification | Solid Phase Affinity Chromatography |
Conjugation | Unconjugated |
Storage | Store lyophilized at 2-8°C for 6 months or at -20°C long term. After reconstitution store the antibody undiluted at 2-8°C for one month or (in aliquots) at -20°C long term. If a slight precipitation occurs upon storage, this should be removed by centrifugation. Avoid repeated freezing and thawing. |
Stability | Shelf life: one year from despatch. |
Shipping | Ambient |
Database Link | |
Background | Luciferase from the firefly has become one of the more widely used reporter proteins for the study of gene expression. Luciferase catalyzes a bioluminescent reaction which requires the substrate luciferin as well as Mg2+ and ATP. Mixing these reagents with the cell extract containing luciferase, results in a flash of light that decays rapidly. This light can be detected by a luminometer. The total light emission is proportional to the luciferase activity of the sample. |