Vinculin (VCL) Human shRNA Plasmid Kit (Locus ID 7414)

CAT#: TR308430

VCL - Human, 4 unique 29mer shRNA constructs in retroviral untagged vector, 5µg of each construct provided


USD 883.00

2 Weeks*

Size
    • 1 kit

Product Images

Frequently bought together (2)
TurboFectin Transfection Reagent (1 mL in 1 vial)
    • 1 ml in 1 vial

USD 507.00


Rabbit Polyclonal Vinculin Antibody
    • 100 ug

USD 570.00

Specifications

Product Data
Locus ID 7414
Synonyms CMD1W; CMH15; HEL114; MV; MVCL
Vector pRS
E. coli Selection Ampicillin
Mammalian Cell Selection Puromycin
Format Retroviral plasmids
Kit Components VCL - Human, 4 unique 29mer shRNA constructs in retroviral untagged vector(Gene ID = 7414). 5µg purified plasmid DNA per construct
29-mer scrambled shRNA cassette in pRS Vector, TR30012, included for free.
RefSeq NM_003373, NM_014000, NM_003373.1, NM_003373.2, NM_003373.3, NM_014000.1, NM_014000.2, BC039174, BC039174.1, BC013847, NM_014000.3, NM_003373.4
UniProt ID P18206
Summary Vinculin is a cytoskeletal protein associated with cell-cell and cell-matrix junctions, where it is thought to function as one of several interacting proteins involved in anchoring F-actin to the membrane. Defects in VCL are the cause of cardiomyopathy dilated type 1W. Dilated cardiomyopathy is a disorder characterized by ventricular dilation and impaired systolic function, resulting in congestive heart failure and arrhythmia. Multiple alternatively spliced transcript variants have been found for this gene, but the biological validity of some variants has not been determined. [provided by RefSeq, Jul 2008]
shRNA Design These shRNA constructs were designed against multiple splice variants at this gene locus. To be certain that your variant of interest is targeted, please contact techsupport@origene.com. If you need a special design or shRNA sequence, please utilize our custom shRNA service.
Performance Guaranteed OriGene guarantees that the sequences in the shRNA expression cassettes are verified to correspond to the target gene with 100% identity. One of the four constructs at minimum are guaranteed to produce 70% or more gene expression knock-down provided a minimum transfection efficiency of 80% is achieved. Western Blot data is recommended over qPCR to evaluate the silencing effect of the shRNA constructs 72 hrs post transfection. To properly assess knockdown, the gene expression level from the included scramble control vector must be used in comparison with the target-specific shRNA transfected samples.

For non-conforming shRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the shRNA kit. To arrange for a free replacement with newly designed constructs, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled shRNA control (Western Blot data preferred).

{0} Product Review(s)

0 Product Review(s) Submit review

Be the first one to submit a review

Product Citations

*Delivery time may vary from web posted schedule. Occasional delays may occur due to unforeseen complexities in the preparation of your product. International customers may expect an additional 1-2 weeks in shipping.