WHSC1 Human siRNA Oligo Duplex (Locus ID 7468)

CAT#: SR305101

NSD2 (Human) - 3 unique 27mer siRNA duplexes - 2 nmol each


USD 518.00

In Stock*

Size
    • 1 kit

Product Images

Frequently bought together (3)
siTran 2.0 siRNA transfection reagent (0.5ml)
    • 500 ul

USD 271.00


Trilencer-27 Fluorescent-labeled transfection control siRNA duplex - 1 nmol
    • 1 nmol

USD 142.00


WHSC1 Rabbit polyclonal Antibody
    • 100 ul

USD 365.00

Other products for "NSD2"

Specifications

Product Data
Purity HPLC purified
Quality Control Tested by ESI-MS
Sequences Available with shipment
Components NSD2 (Human) - 3 unique 27mer siRNA duplexes - 2 nmol each (Locus ID 7468)
Included - SR30004, Trilencer-27 Universal Scrambled Negative Control siRNA Duplex - 2 nmol
Included - SR30005, RNAse free siRNA Duplex Resuspension Buffer - 2 ml
Stability One year from date of shipment when stored at -20°C.
Number of Transfections Approximately 330 transfections/2nmol in 24-well plate under optimized conditions (final conc. 10 nM).
Note Single siRNA duplex (10nmol) can be ordered.
Reference Data
RefSeq NM_001042424, NM_007331, NM_014919, NM_133330, NM_133331, NM_133332, NM_133333, NM_133334, NM_133335, NM_133336
UniProt ID O96028
Synonyms KMT3F; KMT3G; MMSET; REIIBP; TRX5; WHS; WHSC1
Summary This gene encodes a protein that contains four domains present in other developmental proteins: a PWWP domain, an HMG box, a SET domain, and a PHD-type zinc finger. It is expressed ubiquitously in early development. Wolf-Hirschhorn syndrome (WHS) is a malformation syndrome associated with a hemizygous deletion of the distal short arm of chromosome 4. This gene maps to the 165 kb WHS critical region and has also been involved in the chromosomal translocation t(4;14)(p16.3;q32.3) in multiple myelomas. Alternative splicing of this gene results in multiple transcript variants encoding different isoforms. Some transcript variants are nonsense-mediated mRNA (NMD) decay candidates, hence not represented as reference sequences. [provided by RefSeq, Jul 2008]
Performance Guaranteed OriGene guarantees that at least two of the three Dicer-Substrate duplexes in the kit will provide at least 70% or more knockdown of the target mRNA when used at 10 nM concentration by quantitative RT-PCR when the TYE-563 fluorescent transfection control duplex (cat# SR30002) indicates that >90% of the cells have been transfected and the HPRT positive control (cat# SR30003) provides 90% knockdown efficiency.

For non-conforming siRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the siRNA kit. To arrange for a free replacement with newly designed duplexes, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled siRNA control (quantitative RT-PCR data required).

{0} Product Review(s)

0 Product Review(s) Submit review

Be the first one to submit a review

Product Citations

*Delivery time may vary from web posted schedule. Occasional delays may occur due to unforeseen complexities in the preparation of your product. International customers may expect an additional 1-2 weeks in shipping.