C3 Goat Polyclonal Antibody

CAT#: AP21439FC-N

C3 goat polyclonal antibody, FITC

Conjugation: Biotin FITC HRP


USD 540.00

2 Weeks*

Size
    • 1 ml

Product Images

Specifications

Product Data
Applications ID, IF, IHC, IP
Recommended Dilution This Fluorescent immunoconjugate antibody to Rat C3c is used to determine the presence and pattern of C3 in tissue lesions using immunohistochemical staining techniques. Locally deposited immune complexes in tissue usually contain
complement, pointing to activation of the classical pathway. Complement activation in vivo implies active disease and may contribute to the elicitation of the pathogenesis and he extent of tissue destruction. Sometimes the diagnosis can be based on directly on laboratory findings.
Recommended Dilutions: 1/20-1/80.
Reactivities Rat
Host Goat
Isotype IgG
Clonality Polyclonal
Immunogen C3c isolated and purified from pooled normal Rat serum.
Freund’s complete adjuvant is used in the first step of the immunization procedure.
Specificity In Immunoelectrophoresis against fresh Rat serum, a single precipitin line is obtained in the beta-1 region representing native C3.
Against serum containing partly activated C3, a precipitin line is obtained which extends from the beta-1 into the alpha-2 region, demonstrating a gradient. In old serum containing totally activated C3 a single precipitin line in the alpha-2 region is obtained. Antisera to C3c cab also react with the fragments C3b, C3bi and smaller fragments, since they all carry antigenic determinants of the C3c domain.
The product does not react with any other protein components of Rat serum or plasma.
Cross-reactivity:
The antiserum does not cross-react with any other component of Rat plasma. Inter-species cross-reactivity is a normal feature of antibodies to plasma proteins since they frequently share antigenic determinants. Cross-reactivity of this antiserum has not been tested in detail.
Adsorption:
Immunoaffinity adsorbed using insolubilized antigens as required, to eliminate antibodies cross-reacting with other with other plasma proteins. The use of insolubilized adsorption antigens prevents the presence of excess adsorbent protein or immune complexes in the antiserum.
Formulation PBS, pH 7.2 without preservatives and foreign proteins
Label: FITC
State: Lyophilized hyperimmune IgG fraction
Label: Fluorescein Isothiocyanate Isomer 1
Absorption emission: 492 nm / 515 nm
Molar radio: Fluorescein/IgG ~1.8
Reconstitution Method Restore by adding 1.0 ml of sterile distilled water
Concentration lot specific
Purification The IgG fraction is isolated and purified from the antiserum and contains the bulk of the defined antibody specificity. It is free of other serum proteins as tested by immunoelectrophoresis and double radial immunodiffusion
Conjugation FITC
Storage Store the antibody lyophilized at 2-8°C and reconstituted at 2-8°C for one week or (in aliquots) at -20°C for longer.
If a slight precipitation occurs upon storage, this should be removed by centrifugation.
Stability Shelf life: one year from despatch.
Gene Name complement component 3
Background C3 is the most abundant complement protein in rat serum. Its biological function strongly resembles that of C3 in man and other laboratory animal species. It has a central role in the activation system being common to both pathways.
Activation of C3 is achieved by very specific limited proteolysis resulting in the release of a number of degradation fragments. The anaphylotoxin C3a promotes smooth muscle contraction and increases vascular permeability: the large C3b fragment is involved in binding to the complement activator and can be interact with specific receptors to allow efficient clearance of the activating cell or particle; degradation fragments of C3b (C3bi, C3c, C3dg C3d) are important in receptor binding and clearance mechanisms, in virus neutralization and possibly in the immune response.
Synonyms CPAMD1, Complement component 3
Note This immunoconjugate is not pre-diluted. The optimum working dilution of each conjugate should be established by titration before being used. Excess labelled antibody must be avoided because it may cause high unspecific background staining and interfere with the specific signal.
Reference Data

{0} Product Review(s)

0 Product Review(s) Submit review

Be the first one to submit a review

Product Citations

*Delivery time may vary from web posted schedule. Occasional delays may occur due to unforeseen complexities in the preparation of your product. International customers may expect an additional 1-2 weeks in shipping.